« Home « Kết quả tìm kiếm

Linear sweep voltammetry


Tìm thấy 11+ kết quả cho từ khóa "Linear sweep voltammetry"

Development of a spiramycin sensor based on adsorptive stripping linear sweep voltammetry and its application for the determination of spiramycin in chicken egg samples

tailieu.vn

Development of a spiramycin sensor based on adsorptive stripping linear sweep voltammetry and its application for the determination of spiramycin in chicken egg. Moreover, the previous pharmacokinetic studies [2,3] of veterinary drugs in eggs showed that the risk of spiramycin residue in the egg is quite excessive. Therefore, accurate, simple, and precise analytical methods need to be developed for the determination of spiramycin in poultry products..

Cellulose phủ nickel ứng dụng cho quá trình oxi hóa điện hóa ethanol

tailieu.vn

Hoạt tính điện hóa của xúc tác Ni/cellulose cũng được khảo sát bằng phương pháp quét thế vòng tuần hoàn (cyclic voltammetry - CV), quét thế tuyến tính (linear sweep voltammetry – LSV) và chronoamperometry - CA. Kết quả đặc tính cho thấy các hạt Ni kích thước nano phân bố không đồng đều trên mạch cellulose, xúc tác Ni/cellulose cho thấy hoạt tính điện hóa cao và ổn định đối với quá trình điện hóa ethanol.

Cellulose Phủ Nickel Ứng Dụng Cho Quá Trình Oxi Hóa Điện Hóa Ethanol

www.academia.edu

Hoạt tính điện hóa của xúc tác Ni/cellulose cũng được khảo sát bằng phương pháp quét thế vòng tuần hoàn (cyclic voltammetry - CV), quét thế tuyến tính (linear sweep voltammetry – LSV) và chronoamperometry - CA. Kết quả đặc tính cho thấy các hạt Ni kích thước nano phân bố không đồng đều trên mạch cellulose, xúc tác Ni/cellulose cho thấy hoạt tính điện hóa cao và ổn định đối với quá trình điện hóa ethanol.

Improvement of the performance of the positive electrode in t he lead/acid battery by addition of boric acid

tailieu.vn

In the present paper, the effect of boric acid on the kinetics of the PbO2/PbSO4 couple was investigated using linear sweep voltammetry, constant potential, and impedance techniques.. The frequency range of the system is from 0.1 Hz to 100 kHz. For the lead elec- trode in sulfuric acid solutions, the linear sweep vol- tammograms are well identified [21-25]. In our inves- tigations, the lead electrode was cycled in 4.5 M H z S O 4 containing different concentrations of boric acid at 45.

Sensitive determination of hydrazine using poly(phenolphthalein), Au nanoparticles and multiwalled carbon nanotubes modified glassy carbon electrode

tailieu.vn

The fabricated electrode was analysed the determination of hydrazine using cyclic voltammetry, linear sweep voltammetry and amperometry. The peak potential of hydrazine oxidation on bare GCE, poly(PP)/GCE, CNT/GCE, CNT/. A shift in the overpotential to more negative direction and an enhancement in the peak current indicated that the AuNPs/CNT/poly(PP)/GC electrode presented an efficient electrocatalytic activity toward oxidation of hydrazine.

Low loaded Pt-Co catalyst surfaces optimized by magnetron sputtering sequential deposition technique for PEM fuel cell applications: Physical and electrochemical analysis on carbon paper support

tailieu.vn

The electrochemical activities of the catalysts were investigated in electrolyte solution using basic electrochemical methods such as cyclic voltammetry (CV) and linear sweep voltammetry (LSV) with computer controlled AFCBP1 model Pine Bipotentiostat. Mass transfer corrected Tafel plots were constructed with kinetic current density, which was extracted from Koutecky Levich (K–L) plots, and apparent exchange current density, j o ap , of the ORR was calculated.

Voltammetric determination of glycopyrrolate in a pharmaceutical formulation

tailieu.vn

The aim of this work is the determination of glycopyrrolate in pharmaceutical preparations using different voltammetric techniques, namely linear sweep voltammetry (LSV), cyclic voltammetry (CV), and differential pulse voltammetry (DPV).. The CV method was used to study the electroactivity of glycopyrrolate.

Electrochemistry of Fe(IV) and Mn(IV) corroles containing meso-dichlorophenyl substituents and the use of these compounds as catalysts for the electroreduction of dioxygen in acid media

tailieu.vn

Cyclic voltammetry combined with linear sweep voltammetry at a rotating disk electrode (RDE) and a rotating ring disk electrode (RRDE) was utilized to evaluate the catalytic activity for the electroreduction of O 2 . The structures of these compounds are shown in the Chart. We have earlier examined numerous cobalt triarylcorroles as to their catalytic properties for the reduction of O 2 and demonstrated that the type and position of substituents on the 3.

Glucose oxidase immobilized biofuel cell flow channel geometry analysis by CFD simulations

tailieu.vn

Open circuit potential, chronoamperometry, linear sweep voltammetry, and short-circuit current measurements were performed to determine kinetic parameters and other properties of the immobilized enzyme electrode for the modeling study [19,20].. Power generation with enzymatic biofuel cells is proportional to the electrode surface area that provides space for the substrate (i.e. fuel) to react with the immobilized enzyme on the electrode.

Comparison of influence of nanomaterials on a glassy carbon paste electrode-based bioanode in biofuel cells

tailieu.vn

However, before investigating their performance in BFCs, MnO 2 np and Al 2 O 3 –TiO 2. nanostructure modified GOx/GCPE bioanodes’ electrochemical performance was examined by using linear sweep voltammetry (LSV). Measurements were recorded between –0.2 and 1.2 V at a scan rate of 10 mV s − 1 with nanostructure-free and modified GOx/GCPE electrodes in 20 mM BQ and 250 mM glucose containing 10 mL of 100 mM PBS. A comparison of the voltammograms is given in Figure 2.

Stability improvement by crosslinking of previously immobilized glucose oxidase on carbon nanotube-based bioanode

tailieu.vn

Open circuit potential, chronoamperometry, linear sweep voltammetry, and short-circuit current measurements were used to determine the kinetic parameters of the immobilized enzyme on the electrode [16]. Reference 600R) was used for the electrochemical measurements.. Covalently immobilized GOx on the electrode was crosslinked covalently with glutaraldehyde under mild con- ditions by employing crosslinker concentrations of 0.5%–2% to obtain a more stable enzyme electrode.

Fabrication and characterization of enhanced hydrazine electrochemical sensor based on gold nanoparticles decorated on the vanadium oxide, ruthenium oxide nanomaterials, and carbon nanotubes composites

tailieu.vn

Linear sweep voltammetry (LSV) and amperometry were used to determine the hydrazine in pH 10.0 PBS at AuNPs/(VOx- RuOx)/CNT/GCE. LSV was studied with a wide range of hydrazine concentrations µM). The oxidation peak shifted to the positive direction potentials, increasing the concentration of hydrazine.

An ionic liquid/bismuth film-modified sensor for the electrochemical detection of cefixime

tailieu.vn

sweep voltammetry was studied by Ensafi and Allafchian. reported a voltammetric sensor based on a molecularly imprinted polymer grafted on multiwall carbon nanotubes for the quantification of CEF. 16 To the best of our knowledge, there are no articles about voltammetric or amperometric determination of CEF utilizing ionic liquids with a bismuth film-modified electrode, which is the main goal of this study.. 34,35 IL/Bi- modified PGE surfaces have never been used in any electrochemical detection

Effect of the chemical vapor deposition condition on the electrochemically catalytic efficiency for hydrogen evolution reaction in MoS2 nanoparticles

tailieu.vn

The three electrodes configuration, including graphite rod (i.e., counter electrode), Ag/AgCl (i.e., reference electrode), and MoS 2 nanoparticles on graphite foil (i.e., working electrode) was employed to plot the lin- ear sweep voltammetry (LSV) and cyclic voltamme- try (CV). The morphology of MoS 2 nanoparticles was observed by FESEM images, as shown in Figure 2.

Cyclic voltammetry behavior of tamoxifen in different electrolytes, electrochemical characterization, and its measurement by differential pulse anodic voltammetry

tailieu.vn

Cyclic voltammetry behavior of tamoxifen in different electrolytes,. electrochemical characterization, and its measurement by differential pulse anodic voltammetry. Abstract: Cyclic voltammetry (CV) was performed on tamoxifen (tam) using different electrodes and in various acidic electrolytes containing 10% v v − 1 methanol (MeOH). Tam oxidation was found to be most favorable using 0.1 mol L − 1 H 2 SO 4 .

Determination of zineb in tap water and tomato samples by adsorptive catalytic stripping voltammetry

tailieu.vn

The calibration graph for the accumulation time of 60 s was linear in the concentration range of µ M (7.2–1925 µ g/L) and obeyed the equation I p = 211.61C Z. the peak current (in nA) and the concentration of zineb (in µ M), respectively. On the other hand, a calibration graph was also constructed under the conditions given in the literature 2 for determination of zineb for 60-s accumulation time in the absence of S 2 O 2 8 − by adsorptive stripping voltammetry.

Application of experimental design on determination of aluminum content in saline samples by adsorptive cathodic stripping voltammetry

tailieu.vn

Stripping voltammetry, on the other hand, provides an inexpensive way for sensitive and selective analysis in saline matrices. 9 However, direct electrochemical detection of aluminum is difficult since it is reduced at very negative potentials.

Non-linear energy harvesting from coupled impacting beams

tailieu.vn

The frequency sweep study shows the sensitivity of the power generated to the contact stiffness, damping and clearance between the beams. The power generated by the coupled system from the non-linear impact is sensitive to the thickness ratio of the beams and the clearance. The variation in thickness ratio alters the spacing of the natural frequencies of the system which causes modes to interact.

Linear Block Code

tailieu.vn

Linear block code (n,k). A set with cardinality is called a linear block code if, and only if, it is a . subspace of the vector space. Linear block codes – cont’d. The Hamming weight of vector U, denoted by w(U), is the number of non­zero elements in U.. The Hamming distance between two vectors U and V, is the number of elements in which they differ. is the transition probability or bit error probability over channel. Linear block codes –cont’d. elements in the codeword are information bits..