« Home « Kết quả tìm kiếm

Locking plate


Tìm thấy 11+ kết quả cho từ khóa "Locking plate"

Comparison of a ceiling-mounted 3D fat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems

tailieu.vn

conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems. Objectives: To compare intraoperative 3D fluoroscopy with a ceiling-mounted flat panel detector in plate osteosyn- thesis of distal radius fractures (AO/OTA 2R3C1.2) with volar locking plate systems to conventional 2D fluoroscopy for detection of insufficient fracture reduction, plate misplacement and protruding screws..

Outcome of the treatment of the intertrochanteric femoral with the osteosynthesis by locking plate in Tay Nguyen General Hospital

tailieu.vn

To evaluate of the outcome of the treatment of the intertrochanteric femur fracture by proximal femoral locking plate.. 61 patients with proximal femur fractures treated with proximal femoral locking plate from September 2015 to May 2020 in Tay Nguyen General Hospital.. Intertrochanteric femur fractures type A1, A2, and A3 in AO/ASIF classification were treated with a proximal femoral locking plate.. Figure 1: Osteosynthesis by proximal femoral locking plate..

Comparing the locking screw direction of three locking plates for lateral clavicle fractures: A simulation study

tailieu.vn

The lateral clavicle locking plate has a higher union rate and lower complication rate than the hook plate. however, it cannot achieve strong fixation with a small lateral fragment using the locking plate because of the limited number of screw insertions.

Excellent clinical and radiological outcome following locking compression plate fixation of displaced medial clavicle fractures

tailieu.vn

Data is given in terms of the arithmetic mean ± standard deviation. 3 Humeral head fx (Neer IV.2), Subdural hemorrhage Locking plate fixation of the humeral head 2. Serial Rib fx Locking plate fixation of the humeral head 2. Scapula Fx) Double Plate fixation of the clavicle (LCP) prox. Between September 2012 and December 2019 18 patients with a mean age of years were operatively treated for a displaced medial clavicle fracture using an anatomically precontoured locking compression plate (Fig.

Os acromiale may be a contraindication of the clavicle hook plate: Case reports and literature review

tailieu.vn

The oblique T-shaped locking plate with a low profile allows multiple locking screws into both the small distal fragment and the long proximal fragment and can conform to the anatomical shape of the clavicle, providing superior rigid fixation to K-wire and tension-band wires [23, 24].. The smaller size of the coracoid process in Asians may.

Minimizing the complications of intramedullary nailing for distal third tibial shaft and metaphyseal fractures

tailieu.vn

Twenty two patients underwent minimally invasive treatment for closed fractures of distal tibia with locking plate reduction under C-arm. Conclusion: Minimally invasive treatment for fractures of distal tibia with locking plate reduction under C-arm is an effective treatment for distal tibia, which avoids the complications associated with other traditional methods of internal fixation and/or external fixation.. Keywords: Distal tibia fracture. Minimally invasive. Locking compression plate..

Sản phẩm nhiệt luyện

www.academia.edu

STT Tên sản phẩm Hình ảnh Tấm nẹp ép thẳng 1,5mm 1 (LCP Plate 1.5, straight) Tấm nẹp thẳng 1,5 mm 2 (Locking Plate 1.5, straight) Tấm nẹp chữ T 1,5 mm 3 (Locking T-Plate 1.5) Tấm nẹp chữ Y 1,5 mm 4 (Locking Y-Plate 1.5) Tấm nẹp lồi 1,5 mm 5 (Locking Condylar Plate 1.5)

The treatment of posterolateral tibial plateau fracture with a newly designed anatomical plate via the trans-supra-fibular head approach: Preliminary outcomes

tailieu.vn

A Novel Design of a Plate for Posterolateral Tibial Plateau Fractures Based on Computed Tomography Mapping of the Proximal Tibiofibular Joint. A new anatomic locking plate for the treatment of posterolateral tibial plateau fractures. Posterior tibial plateau fracture treatment with the new WAVE posterior proximal tibia plate: feasibility and first results.

Total wrist arthrodesis with and without arthrodesis of the carpoMetacarpal joint (WAWWAM): Study protocol

tailieu.vn

Nonspanning Total wrist arthrodesis with a low-profile locking plate. Available from:. https://doi.org/10.1055/s-00000183.. Three-dimensional kinematic analysis of the second through fifth carpometacarpal joints. https://doi.org/10.101 6/j.jhsa . High re-operation and complication rates 11 years after arthrodesis of the wrist for non-inflammatory arthritis. https://doi.org X.101B7.BJJ-2018-0943.R4.

Medial patellofemoral ligament reconstruction combined with biplanar supracondylar femoral derotation osteotomy in recurrent patellar dislocation with increased femoral internal torsion and genu valgum: A retrospective pilot study

tailieu.vn

Of note, it is important to place the Tomofix- locking plate fixation in a position where they do not impede the later positioning of the femoral tunnel of MPFL. MPFL reconstruction. Two bony grooves were drilled in the patellar medial edge, which were placed into the center and the upper inner corner of the patel- lar medial edge, respectively.

Modified F configuration in the treatment of Pauwels type III femoral neck fracture: A finite element analysis

tailieu.vn

Outcome of cloverleaf locking plate fixation for femoral neck fractures in young adults.. https://doi.org/10.1016/S . Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis. Unique stability of femoral neck fractures treated with the novel biplane double-supported screw fixation method: a biomechanical cadaver study. https://doi.org/10.1 016/j.injury .

Specifying Locking Hints in a SQL Server Database

tailieu.vn

READCOMMITTED Use the same locking as a transaction with an isolation level of READ COMMITTED.. REPEATABLEREAD Use the same locking as a transaction with an isolation level of REPEATABLE READ.. SERIALIZABLE Use the same locking as a transaction with an isolation level of SERIALIZABLE.. SQL Server locking hints for granularity Locking. SQL Server Locking Hints for Other Functions Locking. Applies only to transactions with an isolation level of READ COMMITTED.

Avoiding Locking Scenarios

tailieu.vn

DB2_SKIPINSERTED to skip/ignore uncommitted inserted rows – DB2_SKIPDELETED to skip/ignore uncommitted deleted rows – DB2_EVALUNCOMMITTED to defer locking until row is known to. Skips deleted rows on table scans.. allows DB2 to maintain the table lock when an uncommitted read or cursor stability isolation level is closed. The table lock is released at the end of the transaction.

Incisional paresthesia following clavicle plate fixation: Does it matter to patients?

tailieu.vn

Cutaneous hypoesthesia following plate fixa- tion in clavicle fractures. Kundangar R, Singh KA, Mohanty SP, et al. Clinical outcome of internal fixation of middle third clavicle fractures using locking compression plate:. Natural history of anterior chest wall numbness after plating of clavicle fractures: educating patients. d’Heurle A, Le T, Grawe B, et al. Perioperative risks associated with the opera- tive treatment of clavicle fractures. Wang K, Dowrick A, Choi J, et al.

Compound Plate System

tailieu.vn

FIBRO Compound Plate System. can be used as an alternative to hose- interconnected gas spring. no hose connections necessary. approved to Pressure Equipment Directive 97/23/EC and assembled ready to install. use of standard gas springs with base connection. customer-specific design of the FIBRO Compound Plate System by qualified engineers. gas springs available from stock. control fitting with hoses or mounted directly on the Compound Plate System.

Create New Event Monitor For Locking

tailieu.vn

Create New Event Monitor For Locking. SYSIBMADM.LOCK_EVENT. SYSIBMADM.LOCK_EVENT_PARTICIPANTS. Essential Monitoring Targets – BP Hit Ratio. Hit Ratio for All Data,Index, and XDA for each Bufferpool. SUBSTR(bp_name ,1,30) as BPNAME, data_hit_ratio_percent as DATA_HR, index_hit_ratio_percent as INDEX_HR. xda_hit_ratio_percent as XDA_HR.

One-year follow-up after treatment of proximal and/or middle one-third humeral shaft fractures with a helical plate: Healing rates, complications and functional outcome measures

tailieu.vn

Helical plate fixation for treatment of comminuted frac- tures of the proximal and middle one-third of the humerus. Minimally invasive plate Osteosyn- thesis using a helical plate for Metadiaphyseal complex fractures of the proximal Humerus. Analysis of the helical plate for bone fracture fixation. A clinical method of functional assessment of the shoulder. Minimally invasive percutane- ous plating of proximal humeral shaft fractures with the proximal Humerus internal locking system (PHILOS)

Installing the Cable Distribution Plate

tailieu.vn

6 Installing the Cable Distribution Plate. Installing the cable distribution plate. Installation Manual 6Installing the Cable Distribution Plate. 6 Installing the Cable Distribution Plate. This chapter guides you to install the cable distribution plate.. One cable distribution plate is delivered with one subrack.

Thép tấm nhám ( CHEQUERED PLATE) SS400111

www.scribd.com

10/31/2019 Thép tấm nhám ( CHEQUERED PLATE) SS400Hotline Trang chủ Giới thiệu Sản phẩm Đặt hàng Liên hệ Thư điện tử thép hình, thep hinh, bảng giá thép hình, thephinh.com.vn SẢN PHẨM Bảng giá Thép tấm nhám ( CHEQUERED PLATE) SS400 Thép hình (U, H, L, I, hộp, ống) (Thời gian hiệu lực từ ngày Thép góc ( Equal Angle) Liên hệ trực tiếp để có giá tốt nhất và được tư vấn miễn phí.

Effect of porosity on behaviours of plate structures

tailieu.vn

Effect of Porosity On Behaviours of Plate Structures.. EFFECT OF POROSITY ON BEHAVIOURS OF PLATE STRUCTURES. In this paper, effect of porosity on nonlinear analysis of plate structures is presented. With these approaches, it is easy to fulfil the C1-continuity requirement of the plate model. The obtained results demonstrate the significance of porosity volume fraction, porosity distributions and volume fraction exponent on nonlinear analysis of the plate structures..