Ethernet Distribution Frame


Tóm tắt Xem thử

- Distribution Frames Patch Panels Accessories.
- Glide Cable Manager ...6.
- Patch Panels Introduction ...8.
- T1 Demarcation Modular Patch Panels ...12.
- Category 6 Patch Panels ...13.
- Category 5e Patch Panels ...14.
- Fast Ethernet Patch Panels ...16.
- Multimedia Patch Panels ...17.
- An EDF provides a cross-connect field that ties together all Ethernet network elements from multiple floors of the central office (CO) or point-of-presence (POP), providing a common craft interface for performing adds, upgrades, and rearrangements on Ethernet services.
- Technicians isolate elements, connect new elements, route around problems, and perform maintenance and other functions using semi-permanent patch cord connections on the front of the EDF cross-connect bay.
- Factory assembled cable assemblies and patch panels reduce installation time and ensure consistent quality.
- Turning-up new service is accomplished by plugging in a patch cord instead of the labor-intensive task of making multiple hard-wired cable connections.
- Creating a craft-friendly, low-cost Ethernet distribution system fully rated for Gigabit Ethernet consists of the following:.
- Each EDF consists of the following ADC equipment:.
- 19".
- Category 5e patch panels, RJ45/RJ21x, providing up to 864 available Ethernet ports per 7' rack.
- Category 5e patch cords for creating semi-permanent cross-connections Active Network Element Frame.
- One or two Category 5e patch panels, RJ45/RJ21x, mounted at the top of each bay with active network elements mounted below.
- Category 5e patch cords for making permanent RJ45 connections between Ethernet equipment and distribution patch panels at the top of the bay.
- Cross- Connect.
- Factory terminated and tested RJ21x 24-pair Category 5e cable assemblies, up to 90 meters in length Optical Extension Platforms, providing E/O and O/E conversion for distances greater than 100 meters between active equipment.
- All cable assemblies, patch cords, and patch panels should be rated Category 5, 5e, or 6 to ensure Gigabit Ethernet performance, per EIA/TIA 568-B.1 standards for LAN cabling.
- While Gigabit Ethernet is designed to run on Category 5 or higher cabling, Category 5e and Category 6 cables and components are preferred for new build-outs..
- Due to TIA standards that limit the proximity of connection points, limit the number of passive connection points between active equipment to four with length between EDF and active equipment of at least 15 meters to minimize electrical interaction between patch panels..
- Choose preconnectorized patch panels with RJ45 interfaces on the front and RJ21x interfaces on the rear.
- Gold-on-gold contacts between modular interfaces on patch panels are pre-assembled cable assemblies ensure reliable and consistent performance..
- Connect ports to the same side of the same EDF cross-connect bay using vertical cable managers with slack.
- opposite sides of the EDF cross-connect bay..
- Built-in intelligence enables time saving in installation and troubleshooting with full view of UTP and optical link integrity from one end of the circuit..
- 7' EIA 19".
- 48-Port Category 5e Panel.
- Glide Cable Management.
- All changes, circuit rerouting, upgrades, maintenance and other activities are accomplished using semi-permanent patch cords on the front of the EDF cross-connect bay..
- Glide Cable Manager.
- Ordering Number.
- Rear cable management bar, 19".
- EIA 19".
- Patch Panels.
- Next, we will briefly discuss each of the most popular options available so you can draw conclusions based on your network needs..
- Category 5e is currently the minimum TIA recommended category of wiring for new installations..
- Improvements in all electrical parameters are part of the higher TIA Category 6 standard..
- However, as of this writing, the TIA recommends Category 5e over Category 5 as the minimum cabling for new network infrastructure installations..
- Unshielded twisted pair (UTP) cabling provides immunity to electromagnetic interference (EMI) with the properties of the two conductors that make up a transmission pair being twisted together.
- Most of the world uses UTP cabling, with some exceptions located in a few countries in Europe..
- The typical gauge for Category 5e cable is 24 AWG.
- Q: What’s the difference between T568A and T568B?.
- The only difference is the positioning of the Green and Orange pairs of wires (see figure 1).
- A: The reason is outside of the scope of this paper but it is related to old telephone legacy issues..
- Patch Panel Rear Termination Options.
- Many popular data patch panels are designed using 110 IDCs, requiring the manual punchdown termination of each individual wire.
- With this many manual terminations, installation mistakes are common, including incorrect wire mapping (cross-wiring), opens, shorts, and excessive untwisting of the wire pairs..
- For patch-panel-to-patch-panel connections in a data center or telecommunications room, preterminated cable assemblies and connectorized patch panels can improve installation time and connectivity success.
- A preconnectorized solution dramatically decreases the assembly time and increases the quality of the termination, as the contact points are typically gold-on-gold with high contact forces.
- Preconnectorized solutions do require up-front planning — the distances between panels must be determined so the correct cable assembly length can be ordered..
- T1 Demarcation Modular Patch Panels.
- ADC modular T1 demarcation patch panels feature RJ48X or RJ48C wiring with a variety of rear.
- The T1 demarcation patch panels offer the end users a familiar RJ interface by which the T1 signal can be accessed via industry standard RJ45 patch cables..
- 28 RJ48X Wire-wrap 1 RU x 19".
- 14 RJ48X Wire-wrap, front access Wall mount, 3.5".
- x 19".
- MPP-CXZXF4 8 RJ48X Wire-wrap, front access Wall mount, 3.5".
- MPP-CXZXF3 5 RJ48X Wire-wrap, front access Wall mount, 3.5".
- 24 RJ48C 50-pin 1 RU x 19".
- Category 6 Patch Panels.
- 96-Port Patch Panel.
- Rear View, 24-Port Patch Panel.
- 48-Port Patch Panel Features.
- 1 RU 19.0".
- (48.26 x 4.45 cm) 2 RU 19.0".
- (48.26 x 8.89 cm) 4 RU 19.0".
- Description Port Count Wiring Configuration Rack Units Ordering Number Category 6 24 Universal T568A/B 1 ADCPP24C6 patch panels 48 Universal T568A/B 2 ADCPP48C6 96 Universal T568A/B 4 ADCPP96C6 O r d e r i n g I n f o r m a t i o n.
- Category 5e Patch Panels.
- Exceeds Category 5e requirements.
- Category 5e 24 T568B 1 ADCPP245EB110.
- patch panels 24 T568A 1 ADCPP245EA110.
- ADC's RJ45 coupler panel provides feed-through data and voice connectivity on the front and rear for Category 5e and 6 applications.
- Connectivity on the front of the panel accommodates standard RJ45 patch cords.
- Connectivity for hubs, routers and other active equipment on the back of the panel is also designed for RJ45 patch cords – creating a convenient connection field for data applications.
- Fast Ethernet Patch Panels.
- The first step to integrate Fast Ethernet traffic into a twisted pair network is to terminate both station side and equipment side connections on high performance ADC patch panels..
- For the Ethernet switching system, 5100 and 5800 patch panels provide convenient 25-pair (50-pin) female RJ21x connections on the rear, with rugged 8-pin modular jacks on the front.
- 5100 patch panel RJ21x 2 ADCPP245100TEL.
- 5100 patch panel RJ21x 2 ADCPP485100TEL.
- Multimedia Patch Panels.
- Multimedia Patch Panels Feature Single Circuit Access.
- For Category 6 and Category 5e modular jack applications.
- recessed patch panel chassis.
- (48.26 x 4.45 x 1.27 cm) 2 RU 19.0".
- (48.26 x 8.81 x 1.27 cm) 4 RU 19.0".
- Multimedia Patch Panels – 6000 Modular Jacks and Icons.
- Exceeds Category 5e and Category 6 performance requirements.
- *Replace the XX in the ordering number with choice of color, below..
- Icons for flat modular jacks and patch panels.
- Multimedia Patch Panels – 6000 Media Adapters.
- Blank inserts available to fill unused ports on 6000 multimedia patch panels.
- Exceeds Category 5e requirements as well as ISO/IEC 11801 Telecommunications Standards.
- 5100 Patch Panel.
- 5000E Patch Panel.
- 25-Pair Cable Assemblies.
- The 25-pair cable assemblies are Category 5 PowerSum telco cables that provide precise connectivity between Fast Ethernet switches and 5100 or 5800 Patch Panels.