« Home « Kết quả tìm kiếm

Endotracheal tube


Tìm thấy 20+ kết quả cho từ khóa "Endotracheal tube"

Conversion of I-gel to definitive airway in a cervical immobilized manikin: Aintree intubation catheter vs long endotracheal tube

tailieu.vn

When using a conventional endotracheal tube with the i-gel during conversion, however, there is a risk of dis- lodgement of the endotracheal tube due to the different lengths of the endotracheal tube and the i-gel [8]. To compensate for the shortcomings, we custom- made a long endotracheal tube (LET) that facilitates re- moval of a SGA, especially when combined with an i-gel [10–12].

The accuracy of ultrasound to predict endotracheal tube size for pediatric patients with congenital scoliosis

tailieu.vn

Outer and inner diameters of cuffed endotracheal tubes of the used brand*.. ETT: Endotracheal tube. Usefulness of ultrasound for selecting a correctly sized uncuffed tracheal tube for pediatric patients.. Assessment of the subglottic region by ultrasonography for estimation of appropriate size endotracheal tube: a clinical prospective study.

Effects of the anesthesiologist’s experience on postoperative hoarseness after doublelumen endotracheal tube intubation: A single-center propensity score-matched analysis

tailieu.vn

DLT: Double-lumen endotracheal tube. SLT: Single- lumen endotracheal tube. TN, AS and EK made substantial contribution to the interpretation of the data. All authors have read and approved the final version of the manuscript..

Effect of topical ropivacaine on the response to endotracheal tube during emergence from general anesthesia: A prospective randomized double-blind controlled study

tailieu.vn

The endotracheal tube was pulled out when the following parameters were met:. Pa- tients with stable vital signs and Steward score ≥ 6 points were transferred to the general ward..

Respiratory acidosis during bronchoscopyguided percutaneous dilatational tracheostomy: Impact of ventilator settings and endotracheal tube size

tailieu.vn

Adjustment to 12 ml/kg PBW for the purpose of the study was initiated just before the bronchoscope was inserted through the endotracheal tube. V t was then reduced to 6 ml/kg PBW immediately after the bronchoscope was removed from the endotracheal tube. Respiratory rate, PEEP and inspiration-to-expiration ratio were maintained at a level set by the clinician prior to the procedure..

Laryngeal mask airway reduces incidence of post-operative sore throat after thyroid surgery compared with endotracheal tube: A single-blinded randomized controlled trial

tailieu.vn

Laryngeal mask airway reduces incidence of post-operative sore throat after thyroid surgery compared with endotracheal tube:. Background: Sore throat is a remarkable complication after thyroid surgery with endotracheal tube (ETT). Many studies revealed that laryngeal mask airway (LMA) might reduce the incidence and severity of postoperative sore throat. However, little is known about the use of a flexible reinforced LMA (FLMA) in thyroid surgery.

Implementation of the TaperGuard™ endotracheal tube in an unselected surgical population to reduce postoperative pneumonia

tailieu.vn

Tapered-cuff endotracheal tube does not prevent early postoperative pneumonia compared with spherical-cuff endotracheal tube after major vascular surgery: a randomized controlled trial

K-Y™ jelly inhibits increase in endotracheal tube cuff pressure during nitrous oxide exposure in vitro

tailieu.vn

K-Y ™ jelly inhibits increase in endotracheal tube cuff pressure during nitrous oxide exposure in vitro. Background: The increase in endotracheal tube cuff pressure due to nitrous oxide diffusion is a well-known risk during general anesthesia using nitrous oxide. We hypothesized that lubricating endotracheal tube cuffs with K-Y ™ Jelly might inhibit the increase in cuff pressure that occurs during exposure to nitrous oxide..

Effect of endotracheal tube lubrication on cuff pressure increase during nitrous oxide exposure: A laboratory and prospective randomized controlled trial

tailieu.vn

K-Y jelly inhibits increase in endotracheal tube cuff pressure during nitrous oxide exposure in vitro. Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration

Comparison of laryngeal mask airway and endotracheal tube in preterm neonates receiving general anesthesia for inguinal hernia surgery: A retrospective study

tailieu.vn

Comparison of laryngeal mask airway. and endotracheal tube in preterm neonates. receiving general anesthesia for inguinal hernia surgery: a retrospective study. Background: Preterm neonates are at higher risk of developing inguinal hernia, and have an increased risk of periop‑.

A comparison of laryngeal mask airwaysupreme and endotracheal tube use with respect to airway protection in patients undergoing septoplasty: A randomized, single-blind, controlled clinical trial

tailieu.vn

The LMA-S intracuff pressure of 60 cm H 2 O was adjusted to the ETT cuff pressure of 20 cm H 2 O/1 manometer (Portex Cufator Endotracheal Tube Inflator and Manometer, Portex® Limited, Hythe, Kent, United Kingdom) [13]. Successful airway management was confirmed by the lack of sound from leaking air from the mouth, the expansion of the chest during ventilation, five consecutive capnography curves on the monitor, and auscultation.

Vocal cord granuloma after transoral thyroidectomy using oral endotracheal intubation: Two case reports

tailieu.vn

Recently, we encountered two cases of vocal cord granuloma that were suspected to result from intraoperative compression by the oral endotracheal tube.. Cases presentation: Two women underwent transoral endoscopic thyroidectomy with oral endotracheal tubes fixed at the mouth angle. Subsequent strobolaryngoscopy revealed vocal cord granulomas at the side of contact of the endotracheal tube.

Bougies as an aid for endotracheal intubation with the Airway Scope: Bench and manikin comparison studies

tailieu.vn

During attempts at endo- tracheal intubation with an AWS, the curvature of an endotracheal tube and an endotracheal tube guiding chan- nel of the AWS blade determines the direction in which the tube advances. The target symbol is aligned with the glottis to achieve in- sertion of the tube into the trachea [1, 3]. Failure to align the target symbol with the glottis prevents insertion of an endotracheal tube into the trachea, making intubation.

Supraglottic airway versus endotracheal tube during interventional pulmonary procedures – a retrospective study

tailieu.vn

The advantages of the LMA over the tracheal tube or facemask: a meta-analysis. A comparison of the I-gel supraglottic device with endotracheal intubation for bronchoscopic lung volume reduction coil treatment

Impact of changes in head position during head and neck surgery on the depth of tracheal tube intubation in anesthetized children

tailieu.vn

The red dotted line indicates that the distance from tip of the tube to the bulge is 2 cm, which is the ideal position for the endotracheal tube tip. A comparison of three methods for estimating appropriate tracheal tube depth in children. New decision formulas for predicting endotracheal tube depth in children:. Appropriate placement of intubation depth marks in a new cuffed paediatric tracheal tube.

Effects of lubrication on air-sealing performance of a pediatric cuffed tracheal tube

tailieu.vn

Influence of airway pressure on minimum occlusive endotracheal tube cuff pressure. Leakage of fluid past the tracheal tube cuff in a benchtop model. An in vitro study of the compliance of paediatric tracheal tube cuffs and tracheal wall pressure.. Dimensions of the growing trachea related to age and gender. Fit and seal characteristics of a new paediatric tracheal tube with high volume-low pressure polyurethane cuff.

Conversion of an oral to nasal intubation in difficult nasal anatomy patients: Two case reports

tailieu.vn

Oral-to-nasal endotracheal tube exchange in patients with bleeding esophageal varices. Conversion of an oral to nasal orotracheal intubation using an endotracheal tube exchanger

Improving mucosal anesthesia for awake endotracheal intubation with a novel method: A prospective, assessor-blinded, randomized controlled trial

tailieu.vn

Meaning: In awake endotracheal intubation, novel care using oral dyclonine hydrochloride mucilage can provide more favorable intubation conditions and more stable hemodynamics than the standard of care using oropha- ryngeal tetracaine spray.. Awake intubation consists of placing an endotracheal tube in the trachea while a patient continues to breathe spontan- eously.

Postoperative sore throat and subglottic injury after McGrath® MAC videolaryngoscopic intubation with versus without a stylet in patients with a high Mallampati score: A randomized controlled trial

tailieu.vn

In the stylet group (Group S), McGrath® MAC videolaryngoscopic intub- ation was performed with a malleable aluminum stylet.. curvature and preloaded in the endotracheal tube [10].. The tip of a stylet did not protrude beyond the tip of the endotracheal tube. Before insert- ing a styletted endotracheal tube into the glottis, a stylet was slowly removed just in the front of the vocal cord inlet and only the endotracheal tube was advanced into the glottis.