Lab 5.1.4 RJ-45 Jack Punch Down

tailieu.vn

A CAT 5/5e straight- wired patch cable with an RJ-45 connector will normally plug into this data jack or outlet to connect a PC in a work area to the network. Two CAT 5/5e RJ-45 data jacks (one extra for spare. If RJ-45 data jacks are installed on both ends of the cable, the installation can be tested by inserting cable with RJ-45 connectors and a simple cable continuity tester..

Lab 5.1.5 RJ-45 Jack Punch Down

tailieu.vn

A Category 5/5e straight-through patch cable with an RJ-45 connector will normally plug into this data jack or outlet to connect a PC in a work area to the network. Two Category 5/5e RJ-45 data jacks (one extra for spare. If RJ-45 data jacks are installed on both ends of the cable, the installation can be tested by inserting cable with RJ-45 connectors and a simple cable continuity tester..

Cách bấm đầu RJ-45 vào dây cáp UTP

tailieu.vn

Cách b m đ u RJ-45 vào dây cáp UTP? ấ ầ. 1) Dùng dao cắt bỏ lớp vỏ nhựa bọc ngoài một đoạn khoảng 1,5cm ở đầu dây (nên nhẹ tay vì rất dễ cắt đứt luôn vỏ nhựa của từng sợi dây).. 2) Sắp xếp các sợi dây theo thứ tự từ trái qua phải theo sơ đồ sau:. 3 Xanh lá cây­trắng 4 Xanh biển 5 Xanh biển­trắng 6 Xanh lá cây 7 Nâu­trắng .  

Xài cáp quang với RJ-45

tailieu.vn

V y bây gi dùng cách nào đ n i đ ậ ờ ể ố ượ c cáp quang vào cái đ u ầ Rj-45 c a router? N u n i th ng vào Switch 29xx có đ u cho cáp quang 2 đ u ủ ế ố ẳ ầ ở ầ building thì có th tách r i 2 m ng không? ể ờ ạ. N u mu n n i 2 văn phòng v i kho ng cách g n (=<. Có th k t n i hai tòa nhà b ng dây cáp đ ng (lo i cáp đi n tho i). Kho ng cách t i đa 1km2 ả ố. Băng thông kho ng 11mb ả. Giá cũng kho ng h n 800usd cho 1 c p.

KRONE - Catalogue - Industrial - RJ45 for Industrial appication IP67(2)

tailieu.vn

m Black Cat5e Industrial RJ-45 UTP Pigtail m Black Cat5e Industrial RJ-45 UTP Pigtail m Black Cat5e Industrial RJ-45 UTP Patch Cord m Black Cat5e Industrial RJ-45 UTP Patch Cord Field attachable connector for solid core FTP/UTP cable Socket to KRONE IDC termination. In-Line Interconnect. Closure Cap Female - Captive Cord Closure Cap Male - Captive Cord. Single through coupler IP Female to Female

KRONE - Catalogue - Industrial - RJ45 for Industrial appication IP67

tailieu.vn

m Black Cat5e Industrial RJ-45 UTP Pigtail m Black Cat5e Industrial RJ-45 UTP Pigtail m Black Cat5e Industrial RJ-45 UTP Patch Cord m Black Cat5e Industrial RJ-45 UTP Patch Cord Field attachable connector for solid core FTP/UTP cable Socket to KRONE IDC termination. In-Line Interconnect. Closure Cap Female - Captive Cord Closure Cap Male - Captive Cord. Single through coupler IP Female to Female

Các cách bấm dây mạng RJ45

tailieu.vn

Cáp UTP đi v i đ u n i RJ-45 (RJ - Registered Jack), RJ-45 b ng nh a c ng trong su t ớ ầ ố ằ ự ứ ố có 8 chân b ng đ ng, khi đ a đ u dây vào r i dùng kìm b m dây đ b m thì 8 chân ằ ồ ư ầ ồ ấ ể ấ này s ghim vào 8 s i dây CAT-5. Có 2 chu n b m dây đ ẩ ấ ượ ử ụ c s d ng là T568A và T568B. Hình v sau mô t th t các ẽ ả ứ ự dây đ ượ ắ c s p x p khi ta ng a đ u RJ-45 (phía có các chân ti p xúc) và nhìn t trái qua ế ử ầ ế ừ ph i.

Lab 3.1.9d Rollover Cable Construction

tailieu.vn

Prior to starting the lab, the teacher or lab assistant should have a spool of Cat 5 or Cat 5e UTP cable, RJ-45 (8-pin) connectors, an RJ-45 crimping tool and a continuity tester available. Four RJ-45 connectors, two are extra for spares. RJ-45 crimping tools to attach the RJ-45 connectors to the cable ends. An RJ-45 to DB9 female terminal adapter, available from Cisco. Strip 5.08 cm (2 in.) of jacket off of one end of the cable..

Lab 3.1.9c Rollover Cable Construction

tailieu.vn

Prior to starting the lab, the teacher or lab assistant should have a spool of Cat 5 or Cat 5e UTP cable, RJ-45 (8-pin) connectors, an RJ-45 crimping tool and a continuity tester available. Four RJ-45 connectors, two are extra for spares. RJ-45 crimping tools to attach the RJ-45 connectors to the cable ends. An RJ-45 to DB9 female terminal adapter, available from Cisco. Strip 5.08 cm (2 in.) of jacket off of one end of the cable..

Lab 4.2.9e Fluke LinkRunner – Cable and NIC Tests

tailieu.vn

Plug one end of the cable into the RJ-45 LAN port on the LinkRunner and the other end into the LinkRunner RJ-45 MAP port. What is the length of the cable?. What is the length of the cable . Plug one end of the cable into the RJ-45 LAN port on the LinkRunner and the other end into the RJ-45 MAP port. 4 - 4 CCNA 1: Networking Basics v 3.0 - Lab 4.2.9e Copyright  2003, Cisco Systems, Inc.. Plug the cable into the RJ-45 LAN port on the.

CCNA 1 and 2 Companion Guide, Revised (Cisco Networking Academy Program) part 60

tailieu.vn

Step 1 Connect the terminal or PC using the RJ-45–to–RJ-45 rollover cable and an RJ-45–to–DB-9 or RJ-45–to–DB-25 adapter.. Figure 11-4 shows an example of the console connection to a PC, to establish a Hyper- Terminal connection with a PC..

Lab 1.2.5 Connecting Console Interfaces

tailieu.vn

Connect the rollover cable to the router console port, an RJ-45 connector. Next, connect the other end of the rollover cable to the RJ-45 to DB-9 adapter. Finally attach the adapter to a PC serial port, either DB-9 or DB-25, depending on the computer.

Lab 3.1.9e Crossover Cable Construction

tailieu.vn

All 8 conductors (wires) should be terminated with RJ-45 modular. If the patch cable is used between hubs or switches, it is considered to be part of the "vertical". RJ-45 crimping tools to attach the RJ-45 connectors to the cable ends. One end of the cable should be wired to the T568-A standard. Strip 5.08 cm 9 (2in.) of jacket off one end of the cable.. Reorganize the cable pairs into the order of the 568-B wiring standard.

Lab 3.1.9d Crossover Cable Construction

tailieu.vn

All 8 conductors (wires) should be terminated with RJ-45 modular. If the patch cable is used between hubs or switches, it is considered to be part of the "vertical". RJ-45 crimping tools to attach the RJ-45 connectors to the cable ends. One end of the cable should be wired to the T568-A standard. Strip 5.08 cm 9 (2in.) of jacket off one end of the cable.. Reorganize the cable pairs into the order of the 568-B wiring standard.

Lab 4.2.9b Fluke 620 Cable Tester – Faults

tailieu.vn

Place the near end of the cable into the RJ-45 jack labeled UTP/FTP on the tester. Place the RJ-45-RJ-45 female coupler on the far end of the cable. Then insert the cable identifier or wiremap tool into the other side of the coupler. Using the tester TEST function and a Cable ID Unit for UTP, the functionality of the cable can be determined. Perform a basic cable test on each of the cables provided

Lab 4.2.9c Fluke 620 Cable Tester – Length

tailieu.vn

Place the near end of the cable into the RJ- 45 jack labeled UTP/FTP on the tester. Place the RJ-45-RJ-45 female coupler on the far end of the cable, and then insert the cable identifier or wiremap tool into the other side of the coupler. Using the tester TEST function and a UTP Cable ID Unit, the functionality and length of the cable can be determined. Perform a basic cable test on each of the cables provided

Lab 4.2.9a Fluke 620 Cable Tester – Wire Map

tailieu.vn

Place the near end of the cable into the RJ- 45 jack labeled UTP/FTP on the tester. Place the RJ-45-RJ-45 female coupler on the far end of the cable, and then insert the cable Identifier into the other side of the coupler. Using the tester Wire Map function and a Cable ID Unit, the wiring of both the near and far end of the cable can be determined. Perform a Wire Map test on each of the cables provided

Product Information Checklist

tailieu.vn

CAB-OCTAL-ASYNC 4 RJ-45 patch cables. Cisco AS2511-RJ 2 Terminal server with 16 ports. 32 RJ-45 patch cables. Cisco 1516 1 Ethernet Hub or switch

Networking With Vista P2

tailieu.vn

In some cases, a printer comes with a built-in RJ-45 port, so you need only run ethernet cable from the printer to an RJ-45 port in the switch or router.. In that case, you can get a print server that’s a separate box with either a parallel port or a USB port (or both), as well as an RJ-45 port (see Figure 1.15). You connect the printer to the print server’s parallel or USB port, and then connect the print server’s RJ-45 port to the switch or router.. FIGURE 1.15.