KRONE - Guide - HIGHBAND Solution guide

tailieu.vn

Founded in 1928 by Gustav Krone, the KRONE Group is one of the world’s leading suppliers of the interconnection and distribution systems used in telecommunications and data networks.. The use of KRONE’s HIGHBAND TM range within a structured cable system enables highspeed LAN and WAN systems “Maximum Headroom” in transmission performance. It is the only product on the market which...

ADC KRONE - Catalogue - Cat 6 - HighBand 25 - Complete Solution 2006

tailieu.vn

HighBand ® 25. A unique high-density solution with superior cable management.. ADC KRONE’s HighBand ® 25 cross connect solution allows for maximum network throughput beyond one Gigabit and is the platform needed for the most advanced networks.. The HighBand 25 solution is comprised of high performance disconnection modules, user friendly cable management and innovative anti-snag patch cords. HighBand 25 utilises...

KRONE - Datasheet - HIGHBAND - 1 or 2 Pair - Patch Plug Set

tailieu.vn

INSTALLATION INSTRUCTIONS FOR KRONE ® HIGHBAND 1 OR 2 PAIR PLUG SET PRODUCT No. NOTE: BOTH PAIRS CAN BE CONNECTED AND THIS PLUG CAN BE USED FOR 1 PAIR PATCHING WITH HIGHBAND 8 AND 10 DISCONNECTION MODULES OR 2 PAIR PATCHING WITH HIGHBAND 16 AND 20 SWITCHING (DOUBLE DENSITY) MODULES.

KRONE - Datasheet - HIGHBAND - 8 & 10 pr Disconnection Module

tailieu.vn

10 Pair Disconnection Modules. Superior high speed data and voice cross connect modules.. Available in 8 and 10 pair disconnect versions. These modules enable high speed LAN and WAN systems maximum headroom in transmission performance.. These modules can be either patched, jumpered and used in a patch by exception configuration.. Number of patching cycles. .750 Number of wire reterminations. .>200...

KRONE - Datasheet - HIGHBAND - 16 & 20 pr Switching Module

tailieu.vn

20 Pair Switching Modules. PO Box 335 Wyong NSW 2259 2 Hereford Street Berkeley Vale NSW 2261 Telephone Facsimile Toll Free Help Desk Website: www.kroneasia.com Email: [email protected] CD5061 Issue 1. Superior high speed data and voice cross connect modules.. Available in 16 and 20 pair versions. These modules enable high speed LAN and WAN systems maximum headroom in. They are...

KRONE - Datasheet - HIGHBAND - Cat 6 - 25 pr

tailieu.vn

Issue1 - Draft 01/07/04 Form: E104 1of 2 SUBJECT TO CHANGE. The HIGHBAND 25 RANGE of modules provides a 24 pair high-density, high performance, cost competitive Category 6 data grade module, (the 25 th pair is not used) and a high-density cost competitive 25 pair Category 3 voice grade module to accept UTP &. It will supplement the existing HIGHBAND™...

KRONE - Datasheet - HIGHBAND - Cat 6 - Compact8 Disconnection Module

tailieu.vn

Maximum Headroom beyond Enhanced Category 5 transmission performance. Superior high speed data and voice cross connect modules. These modules also enable high speed LAN and WAN systems maximum headroom beyond Enhanced CAT 5. transmission performance. This is proven technology which has become the ‘industry standard‘ in over 60 countries. These modules can be used in a fully patched configuration or...

KRONE - Datasheet - HIGHBAND - Cat 6 - Ultim8 8pr Disconnection Module

tailieu.vn

KRONE HIGHBAND Ultim8™. Maximum Headroom beyond Category 6, Class E transmission performance. Superior high speed data and voice cross connect modules that far exceed Category 6 component standards. HIGHBAND Ultim8 is an 8 pair disconnect module to enable high speed LAN and WAN systems maximum headroom beyond Category 6, Class E transmission performance.. These modules can be used in a...

KRONE - Datasheet - HIGHBAND - Over Voltage Arrestor Magazine

tailieu.vn

Arrestor Magazine 3 Pole Equipped. Overvoltage Protection for HIGHBAND 10. Arrestor Magazine 3 Pole Equipped Overvoltage Protection for HIGHBAND 10. Overvoltage Arrestor Magazine made to suit HIGHBAND™ 10 module, the magazine comes in two equipped variations, 230V and 500V.. Voltage/Current rating at 25°C ambient: ...150V AC at 2.5A max Dielectric strength: ...>. 1.5kV AC Surge voltage strength (1.2/50 µ sec...

KRONE - Datasheet - HIGHBAND - OverVoltage Protection -Arrestor Magazine

tailieu.vn

Arrestor Magazine 3 Pole Equipped. Overvoltage Protection for HIGHBAND 10. Arrestor Magazine 3 Pole Equipped Overvoltage Protection for HIGHBAND 10. Overvoltage Arrestor Magazine made to suit HIGHBAND™ 10 module, the magazine comes in two equipped variations, 230V and 500V.. Voltage/Current rating at 25°C ambient: ...150V AC at 2.5A max Dielectric strength: ...>. 1.5kV AC Surge voltage strength (1.2/50 µ sec...

KRONE - Datasheet - HIGHBAND - Voice & Data PatchCord

tailieu.vn

Superior high speed data and voice cross connection enable high speed LAN and WAN systems maximum headroom in transmission performance. Environment for use: ...Indoors or in dry encloser rated IP54 or greater Operating temperature range: ...-40 o c to +80 o c Maximum relative humidity:...•93% non-condensing Transmission performance and reliability:. Number of patching cycles: ...Ž750 Safety: ...UL 1863 Flammability rating...